器件名称:
MI-26K-IV
功能描述:
50-100 WATTS MILITARY COTS DC/DC CONVERTER
文件大小:
716.14KB 共1页
简 介:
MEDICAL & MILITARY MI-200 Series 5 0 - 1 0 0 W AT T S M I L I TA R Y C O T S D C / D C C O N V E R T E R Features 28Vdc Inputs per MIL-STD-704D/E/F 155Vdc Inputs per MIL-STD-1399A 270Vdc Inputs per MIL-STD-704D/E/F MIL-STD-810 environments OVP and Thermal shutdown Power boosters for higher power Low noise FM control Specifications INPUT Input Voltage No Load Power Dissipation See input voltage chart Typ 1.35W STANDARDS AND APPROVALS Environment (MIL-STD-8100) Altitude – Method 500.2 Humidity – Method 507.2 Acceleration – Method 513.3 0.5% V nom typical 0.05% V nom typical. 10% to full load 0.01%/°C 1%pp V nom 50% - 110% 0.5 V 105% - 125% 20% - 130% Vibration – Method 514.3 Shock – Method 516.3 Reliability (MIL-HDBK-217F) 25°C Ground Benign 50°C Naval Sheltered 65°C Airborne inhabited cargo Derating C-Tick 3,277,000 hours 1,999,000 hours 1,540,000 hours NAVMAT P-4855-1A AS/NZS2064:1997 Group 1 Class AEMC filters supplied with some models 70,000 feet 86/240 (% /hours) 9 g’s 20g’s 40g’s OUTPUT Set point accuracy Load/Line regulation Output temperature drift Output noise Output Voltage Trimming Remote Sense Compensation Current limit Short Circuit Current OPERATING Isolation Input - Output 3,000Vrms Output to Baseplate 500Vrms Input to Baseplate 1,500Vrms 80 – 90% MECHANICAL Weight Dimensions 170 grams 116.8 x 61 x 12.7mm Efficiency ENVIRONMENTAL I Grade Storage Temperature Operating Temperature (baseplate) Power Cycling Burn-in Temperature Cycled With Power off T……