器件名称:
V048F040M015
功能描述:
300W DC/DC VOLTAGE TRANSFORMATION MODULE PRELIMINARY
文件大小:
1163.56KB 共1页
简 介:
MEDICAL & MILITARY MI COMPAC Series 5 0 - 3 0 0 W AT T S M I L I TA R Y R E A D Y T O U S E C O M P O N E N T Features Inputs 28Vdc and 270Vdc Outputs 1 to 3, 1 to 95Vdc EMI Compliance: MIL-STD-461C&D/E Transients & Spikes: MIL-STD-704A, 1275A/B Quality System MIL-1-45208 Reverse polarity protected Low noise FM control Specifications INPUT Nominal input Input range Input spike limit MIL-STD-704A MIL-STD-1275A/B Input surge limit Overvoltage shutdown Inrush current Reverse polarity protection Recommended Fuse 28Vdc 18 – 50Vdc -600V to +600Vdc -250V to +250Vdc 100Vdc 50Vdc 110% 10A 270Vdc 125V – 400Vdc 800Vdc max -600V to +600Vdc 500Vdc 400Vdc 110% of input typical 2A FO3A type ENVIRONMENTAL Storage temperature Operating temperature case Shutdown temperature +100°C +85°C +95°C typical STANDARDS AND APPROVALS EMI/RFI characteristics (MIL-STD-461C, D &E) INPUT POWER LEADS Conduct emissions CE01, CE03, CE07, CE101, CE102 MIL-STD-461C & D (1 Up) CE101 MIL-STD-461E (2 Up & 3Up) CS01, CS02, CS06, CS101, CS114, CS116 MIL-STD-461C & D (1 Up) CS101, CS114, CS116 MIL-STD-461E (2 Up & 3Up) Conducted susceptibility 28Vdc 270Vdc 250W 420Vdc 4A Dual output Triple output OUTPUT Output power Clamp voltage Overload protection Set point accuracy Load/Line regulation Output temperature drift Output noise Output voltage trimming Remote sense compensation Current Limit 250W 60Vdc 20A 0.5% V nom typical 0.2-0.5% V nom typical 0.01%/°C 1%pp V nom 50%-110% 0.5V 105% – 125% Selection ……